India-focused Boiler Engineering Education • BOE • Boiler Inspector Exams
Educational PlatformIndian Boiler Course Learning Centre
Numerical

Blowdown from TDS

Problem

Feedwater TDS is 120 ppm and permissible boiler-water TDS is 3,000 ppm. Steam generation is 20 t/h.

Formula

B=S×Cf/(Cb−Cf)

Solution

B=20×120/(3000−120).

Answer

0.833 t/h

Engineering check