Problem
Feedwater is 52 t/h and steam generation is 50 t/h. Neglect other losses.
Formula
B = F−S
Solution
B=52−50. Blowdown percentage of feedwater=2/52×100.
Answer
2 t/h or 3.85% of feedwater
Engineering check